1-Phase Current Control Relays

December 1, 2021 | POSTED IN: Schneider All Products Products

1-Phase Current Control Relays

[vc_row type="in_container" full_screen_row_position="middle" scene_position="center" text_color="dark" text_align="left" overlay_strength="0.3" shape_divider_position="bottom"][vc_column column_padding="no-extra-padding" column_padding_position="all" background_color_opacity="1" background_hover_color_opacity="1" column_shadow="none" column_border_radius="none" width="1/1" tablet_text_alignment="default" phone_text_alignment="default" column_border_width="none" column_border_style="solid"][vc_column_text]

1-phase current control relays with integrated current transformer - RM17JC

[/vc_column_text][/vc_column][/vc_row][vc_row type="in_container" full_screen_row_position="middle" scene_position="center" text_color="dark" text_align="left" overlay_strength="0.3" shape_divider_position="bottom"][vc_column column_padding="no-extra-padding" column_padding_position="all" background_color_opacity="1" background_hover_color_opacity="1" column_shadow="none" column_border_radius="none" width="2/3" tablet_text_alignment="default" phone_text_alignment="default" column_border_width="none" column_border_style="solid"][vc_column_text]The control relay RM17JC00MW is designed to monitor ∿ currents[/vc_column_text][divider line_type="No Line"][vc_column_text]These control relays allow:
  • Integrated current transformer
  • Measurement range 2…20 A
  • Choice of action on the output relay
  • Clip-on mounting on a rail
They feature a control status indicator LED.[/vc_column_text][/vc_column][vc_column column_padding="no-extra-padding" column_padding_position="all" background_color_opacity="1" background_hover_color_opacity="1" column_shadow="none" column_border_radius="none" width="1/3" tablet_text_alignment="default" phone_text_alignment="default" column_border_width="none" column_border_style="solid"][image_with_animation image_url="11201" alignment="" animation="Fade In" border_radius="none" box_shadow="none" max_width="100%"][/vc_column][/vc_row][vc_row type="in_container" full_screen_row_position="middle" scene_position="center" text_color="dark" text_align="left" overlay_strength="0.3" shape_divider_position="bottom"][vc_column column_padding="no-extra-padding" column_padding_position="all" background_color_opacity="1" background_hover_color_opacity="1" column_shadow="none" column_border_radius="none" width="1/1" tablet_text_alignment="default" phone_text_alignment="default" column_border_width="none" column_border_style="solid"][vc_column_text]

Applications

[/vc_column_text][divider line_type="No Line"][vc_column_text]
  • Load state control of motors and generators
  • Control of current drawn by a 3-phase motor
  • Monitoring of heating or lighting circuits
  • Control of pump draining (undercurrent)
  • Control of overtorque (crushers)
  • Monitoring of electromagnetic brakes or clutches
[/vc_column_text][divider line_type="No Line"][divider line_type="No Line"][vc_row_inner column_margin="default" text_align="left"][vc_column_inner column_padding="no-extra-padding" column_padding_position="all" background_color_opacity="1" background_hover_color_opacity="1" column_shadow="none" column_border_radius="none" width="1/3" column_border_width="none" column_border_style="solid"][/vc_column_inner][vc_column_inner column_padding="no-extra-padding" column_padding_position="all" background_color_opacity="1" background_hover_color_opacity="1" column_shadow="none" column_border_radius="none" width="1/3" column_border_width="none" column_border_style="solid"][nectar_btn size="large" button_style="regular" button_color_2="Extra-Color-2" icon_family="default_arrow" url="https://sg.electgo.com/products?utf8=%E2%9C%93&search=RM17JC00MW" text="Shop RM17JC00MW Now"][/vc_column_inner][vc_column_inner column_padding="no-extra-padding" column_padding_position="all" background_color_opacity="1" background_hover_color_opacity="1" column_shadow="none" column_border_radius="none" width="1/3" column_border_width="none" column_border_style="solid"][/vc_column_inner][/vc_row_inner][/vc_column][/vc_row][vc_row type="in_container" full_screen_row_position="middle" scene_position="center" text_color="dark" text_align="left" overlay_strength="0.3" shape_divider_position="bottom"][vc_column column_padding="no-extra-padding" column_padding_position="all" background_color_opacity="1" background_hover_color_opacity="1" column_shadow="none" column_border_radius="none" width="1/2" tablet_text_alignment="default" phone_text_alignment="default" column_border_width="none" column_border_style="solid"][vc_column_text]

Description

  1. Overcurrent setting potentiometer 2. Spring for clip-on mounting on 35 mm/1.38 in. rail[/vc_column_text][/vc_column][vc_column column_padding="no-extra-padding" column_padding_position="all" background_color_opacity="1" background_hover_color_opacity="1" column_shadow="none" column_border_radius="none" width="1/2" tablet_text_alignment="default" phone_text_alignment="default" column_border_width="none" column_border_style="solid"][image_with_animation image_url="11199" alignment="" animation="Fade In" border_radius="none" box_shadow="none" max_width="100%"][/vc_column][/vc_row][vc_row type="in_container" full_screen_row_position="middle" scene_position="center" text_color="dark" text_align="left" overlay_strength="0.3" shape_divider_position="bottom"][vc_column column_padding="no-extra-padding" column_padding_position="all" background_color_opacity="1" background_hover_color_opacity="1" column_shadow="none" column_border_radius="none" width="1/1" tablet_text_alignment="default" phone_text_alignment="default" column_border_width="none" column_border_style="solid"][vc_column_text]

Operating Principles

[/vc_column_text][vc_column_text]RM17JC00MW[/vc_column_text][divider line_type="No Line"][vc_row_inner column_margin="default" text_align="left"][vc_column_inner column_padding="no-extra-padding" column_padding_position="all" background_color_opacity="1" background_hover_color_opacity="1" column_shadow="none" column_border_radius="none" width="2/3" column_border_width="none" column_border_style="solid"][vc_column_text]Control relay RM17JC00MW is:
  • equipped with an integrated current transformer
  • fault signaling is by LED
An adjustable time delay on threshold crossing, provides immunity to transients, and helps prevent spurious triggering of the output relay[/vc_column_text][/vc_column_inner][vc_column_inner column_padding="no-extra-padding" column_padding_position="all" background_color_opacity="1" background_hover_color_opacity="1" column_shadow="none" column_border_radius="none" width="1/3" column_border_width="none" column_border_style="solid"][image_with_animation image_url="11202" alignment="" animation="Fade In" border_radius="none" box_shadow="none" max_width="100%"][/vc_column_inner][/vc_row_inner][divider line_type="No Line"][vc_column_text]Overcurrent detection[/vc_column_text][divider line_type="No Line"][vc_row_inner column_margin="default" text_align="left"][vc_column_inner column_padding="no-extra-padding" column_padding_position="all" background_color_opacity="1" background_hover_color_opacity="1" column_shadow="none" column_border_radius="none" width="1/2" column_border_width="none" column_border_style="solid"][vc_column_text]
  • Relay RM17JC00MW controls overcurrent.
  • The relay closes when the current exceeds the threshold setting on the front panel and opens when it drops below the threshold minus the hysteresis.
  • When terminal Y1 is linked to A1 (+), the output is reversed. The relay opens when the current exceeds the threshold setting on the front panel and closes again when it drops below the hysteresis value.
[/vc_column_text][/vc_column_inner][vc_column_inner column_padding="no-extra-padding" column_padding_position="all" background_color_opacity="1" background_hover_color_opacity="1" column_shadow="none" column_border_radius="none" width="1/2" column_border_width="none" column_border_style="solid"][image_with_animation image_url="11198" alignment="" animation="Fade In" border_radius="none" box_shadow="none" max_width="100%"][/vc_column_inner][/vc_row_inner][divider line_type="No Line"][vc_row_inner column_margin="default" text_align="left"][vc_column_inner column_padding="no-extra-padding" column_padding_position="all" background_color_opacity="1" background_hover_color_opacity="1" column_shadow="none" column_border_radius="none" width="1/3" column_border_width="none" column_border_style="solid"][/vc_column_inner][vc_column_inner column_padding="no-extra-padding" column_padding_position="all" background_color_opacity="1" background_hover_color_opacity="1" column_shadow="none" column_border_radius="none" width="1/3" column_border_width="none" column_border_style="solid"][nectar_btn size="medium" button_style="regular" button_color_2="Extra-Color-2" icon_family="default_arrow" url="https://sg.electgo.com/products?utf8=%E2%9C%93&search=RM17JC00MW" text="Shop RM17JC00MW Now"][/vc_column_inner][vc_column_inner column_padding="no-extra-padding" column_padding_position="all" background_color_opacity="1" background_hover_color_opacity="1" column_shadow="none" column_border_radius="none" width="1/3" column_border_width="none" column_border_style="solid"][/vc_column_inner][/vc_row_inner][/vc_column][/vc_row][vc_row type="in_container" full_screen_row_position="middle" scene_position="center" text_color="dark" text_align="left" overlay_strength="0.3" shape_divider_position="bottom"][vc_column column_padding="no-extra-padding" column_padding_position="all" background_color_opacity="1" background_hover_color_opacity="1" column_shadow="none" column_border_radius="none" width="1/1" tablet_text_alignment="default" phone_text_alignment="default" column_border_width="none" column_border_style="solid"][vc_column_text]

1-phase current control relays - RM22JA and RM35JA

[/vc_column_text][/vc_column][/vc_row][vc_row type="in_container" full_screen_row_position="middle" scene_position="center" text_color="dark" text_align="left" overlay_strength="0.3" shape_divider_position="bottom"][vc_column column_padding="no-extra-padding" column_padding_position="all" background_color_opacity="1" background_hover_color_opacity="1" column_shadow="none" column_border_radius="none" width="2/3" tablet_text_alignment="default" phone_text_alignment="default" column_border_width="none" column_border_style="solid"][vc_column_text]RM22JA and RM35JA[/vc_column_text][divider line_type="No Line"][vc_column_text]These control relays enable:
  • Automatic or ∿ recognition
  • Selection between overcurrent and undercurrent
  • Measurement as a true rms value
  • Selectable memory function
  • Clip-on mounting on a rail
They feature:
  • Dial pointer LED indicator for relay power ON status
  • Relay output status LED
  • A sealable cover to help protect the settings
  • A control status indicator LED
[/vc_column_text][divider line_type="No Line"][/vc_column][vc_column column_padding="no-extra-padding" column_padding_position="all" background_color_opacity="1" background_hover_color_opacity="1" column_shadow="none" column_border_radius="none" width="1/3" tablet_text_alignment="default" phone_text_alignment="default" column_border_width="none" column_border_style="solid"][divider line_type="No Line"][image_with_animation image_url="11197" alignment="" animation="Fade In" border_radius="none" box_shadow="none" max_width="100%"][image_with_animation image_url="11196" alignment="" animation="Fade In" border_radius="none" box_shadow="none" max_width="100%"][/vc_column][/vc_row][vc_row type="in_container" full_screen_row_position="middle" scene_position="center" text_color="dark" text_align="left" overlay_strength="0.3" shape_divider_position="bottom"][vc_column column_padding="no-extra-padding" column_padding_position="all" background_color_opacity="1" background_hover_color_opacity="1" column_shadow="none" column_border_radius="none" width="1/2" tablet_text_alignment="default" phone_text_alignment="default" column_border_width="none" column_border_style="solid"][nectar_btn size="medium" button_style="regular" button_color_2="Extra-Color-2" icon_family="default_arrow" url="https://sg.electgo.com/products?utf8=%E2%9C%93&search=RM22JA" text="Shop RM22JA Now"][/vc_column][vc_column column_padding="no-extra-padding" column_padding_position="all" background_color_opacity="1" background_hover_color_opacity="1" column_shadow="none" column_border_radius="none" width="1/2" tablet_text_alignment="default" phone_text_alignment="default" column_border_width="none" column_border_style="solid"][nectar_btn size="medium" button_style="regular" button_color_2="Extra-Color-2" icon_family="default_arrow" url="https://sg.electgo.com/products?utf8=%E2%9C%93&search=RM35JA" text="Shop RM35JA Now "][/vc_column][/vc_row][vc_row type="in_container" full_screen_row_position="middle" scene_position="center" text_color="dark" text_align="left" overlay_strength="0.3" shape_divider_position="bottom"][vc_column column_padding="no-extra-padding" column_padding_position="all" background_color_opacity="1" background_hover_color_opacity="1" column_shadow="none" column_border_radius="none" width="1/1" tablet_text_alignment="default" phone_text_alignment="default" column_border_width="none" column_border_style="solid"][vc_column_text]

Applications

[/vc_column_text][divider line_type="No Line"][vc_column_text]
  • Excitation control of DC machines
  • Load state control of motors and generators
  • Control of current drawn by a 3-phase motor
  • Monitoring of heating or lighting circuits
  • Control of pump draining (undercurrent)
  • Control of overtorque (crushers)
  • Monitoring of electromagnetic brakes or clutches
[/vc_column_text][/vc_column][/vc_row][vc_row type="in_container" full_screen_row_position="middle" scene_position="center" text_color="dark" text_align="left" overlay_strength="0.3" shape_divider_position="bottom"][vc_column column_padding="no-extra-padding" column_padding_position="all" background_color_opacity="1" background_hover_color_opacity="1" column_shadow="none" column_border_radius="none" width="1/1" tablet_text_alignment="default" phone_text_alignment="default" column_border_width="none" column_border_style="solid"][vc_column_text]

Description

[/vc_column_text][divider line_type="No Line"][vc_row_inner column_margin="default" text_align="left"][vc_column_inner column_padding="no-extra-padding" column_padding_position="all" background_color_opacity="1" background_hover_color_opacity="1" column_shadow="none" column_border_radius="none" width="1/4" column_border_width="none" column_border_style="solid"][image_with_animation image_url="11194" alignment="" animation="Fade In" border_radius="none" box_shadow="none" max_width="100%"][image_with_animation image_url="11192" alignment="" animation="Fade In" border_radius="none" box_shadow="none" max_width="100%"][/vc_column_inner][vc_column_inner column_padding="no-extra-padding" column_padding_position="all" background_color_opacity="1" background_hover_color_opacity="1" column_shadow="none" column_border_radius="none" width="1/4" column_border_width="none" column_border_style="solid"][image_with_animation image_url="11193" alignment="" animation="Fade In" border_radius="none" box_shadow="none" max_width="100%"][image_with_animation image_url="11191" alignment="" animation="Fade In" border_radius="none" box_shadow="none" max_width="100%"][/vc_column_inner][vc_column_inner column_padding="no-extra-padding" column_padding_position="all" background_color_opacity="1" background_hover_color_opacity="1" column_shadow="none" column_border_radius="none" width="2/4" column_border_width="none" column_border_style="solid"][vc_column_text]1. Configuration: selection of operating mode e <I (undercurrent), >I (overcurrent), >I> (overcurrent and undercurrent), MEMORY - NO MEMORY (with or without memory) 2.  Current threshold setting potentiometer I% 3a. Hysteresis adjustment potentiometer Hys 3b.  Hysteresis/overcurrent and undercurrent window mode adjustment potentiometer Hys/>I> 4. Time delay adjustment potentiometer Tt 5. Diagnostic button  6. Overcurrent setting potentiometer >I[/vc_column_text][/vc_column_inner][/vc_row_inner][/vc_column][/vc_row][vc_row type="in_container" full_screen_row_position="middle" scene_position="center" text_color="dark" text_align="left" overlay_strength="0.3" shape_divider_position="bottom"][vc_column column_padding="no-extra-padding" column_padding_position="all" background_color_opacity="1" background_hover_color_opacity="1" column_shadow="none" column_border_radius="none" width="1/1" tablet_text_alignment="default" phone_text_alignment="default" column_border_width="none" column_border_style="solid"][nectar_animated_title heading_tag="h2" style="color-strip-reveal" color="Accent-Color" text="Enquire Now"][gravityform id="7" title="false" description="false" ajax="false"][/vc_column][/vc_row][vc_row type="in_container" full_screen_row_position="middle" scene_position="center" text_color="dark" text_align="left" overlay_strength="0.3" shape_divider_position="bottom"][vc_column column_padding="no-extra-padding" column_padding_position="all" background_color_opacity="1" background_hover_color_opacity="1" column_shadow="none" column_border_radius="none" width="1/1" tablet_text_alignment="default" phone_text_alignment="default" column_border_width="none" column_border_style="solid"][nectar_animated_title heading_tag="h2" style="color-strip-reveal" color="Accent-Color" text="Discover More "][recent_posts style="default" category="schneider" columns="4" order="DESC" orderby="date" posts_per_page="4" post_offset="2"][/vc_column][/vc_row]

With integrated current transformer – RM17JC

The control relay RM17JC00MW is designed to monitor ∿ currents
 
These control relays allow:

  • Integrated current transformer
  • Measurement range 2…20 A
  • Choice of action on the output relay
  • Clip-on mounting on a ⍽ rail

They feature a control status indicator LED.

Applications

  • Load state control of motors and generators
  • Control of current drawn by a 3-phase motor
  • Monitoring of heating or lighting circuits
  • Control of pump draining (undercurrent)
  • Control of overtorque (crushers)
  • Monitoring of electromagnetic brakes or clutches

Description

The control relay RM17JC00MW is designed to monitor ∿ currents
 
These control relays allow:

  • Integrated current transformer
  • Measurement range 2…20 A
  • Choice of action on the output relay
  • Clip-on mounting on a ⍽ rail

They feature a control status indicator LED.

1. Overcurrent setting potentiometer

2. Spring for clip-on mounting on 35 mm/1.38 in. ⍽ rail

Operating Principles for RM17JC00MW

Control relay RM17JC00MW is:

  • equipped with an integrated current transformer
  • fault signaling is by LED

An adjustable time delay on threshold crossing, provides immunity to transients, and helps prevent spurious triggering of the output relay

Overcurrent detection

  • Relay RM17JC00MW controls overcurrent.
  • The relay closes when the current exceeds the threshold setting on the front panel and opens when it drops below the threshold minus the hysteresis.
  • When terminal Y1 is linked to A1 (+), the output is reversed. The relay opens when the current exceeds the threshold setting on the front panel and closes again when it drops below the hysteresis value.

1-phase current control relays – RM22JA and RM35JA

RM22JA and RM35JA

These control relays enable:

  • Automatic ⎓ or ∿ recognition
  • Selection between overcurrent and undercurrent
  • Measurement as a true rms value
  • Selectable memory function
  • Clip-on mounting on a ⍽ rail

They feature:

  • Dial pointer LED indicator for relay power ON status
  • Relay output status LED
  • A sealable cover to help protect the settings
  • A control status indicator LED

Applications

  • Excitation control of DC machines
  • Load state control of motors and generators
  • Control of current drawn by a 3-phase motor
  • Monitoring of heating or lighting circuits
  • Control of pump draining (undercurrent)
  • Control of overtorque (crushers)
  • Monitoring of electromagnetic brakes or clutches

Description

1. Configuration: selection of operating mode e <I (undercurrent), >I (overcurrent), >I> (overcurrent and undercurrent), MEMORY – NO MEMORY (with or without memory)

2.  Current threshold setting potentiometer I%

3a. Hysteresis adjustment potentiometer Hys

3b.  Hysteresis/overcurrent and undercurrent window mode adjustment potentiometer Hys/>I>

4. Time delay adjustment potentiometer Tt

5. Diagnostic button 

6. Overcurrent setting potentiometer >I