Do you have a socket for model MKS2XPN-11?

Answer : 

There is no such model. You may be looking for MKS2XTN-11 instead, the socket will be P7MF-06.

Looking for equivalent model for PANASONIC LQ RELAY ALQ324 24V 10A.

Answer :

You may select these relays G2R-1A or G2R-1A4. For G2R-1A, the contact rating is 10A at 250VAC/30VDC. For G2R-1A4, the contact rating is 8A at 250VAC/30VDC. The difference is the appearance, dimension, and contact rating. Kindly contact us directly at  for a quotation.

Looking for an equivalent model for
1) Omron Relay Led Indicator, MK3PN-5-1, 230Vac
2) Omron Relay Led Indicator, MK3PND-5-1, 24Vdc

Answer : 

For Omron relay LED Indicator, MK3PN-5-I, you may consider MKS3PN-5. For Omron relay LED indicator, MK3PND-5-I, you may consider MKS3PN-D-5. Kindly contact us directly at  for a quotation.

The clip PYC-P for MY4N-D2 and PYF14A-E is wrong.

Answer : 

The clip model PYC-P is for the PYF08M socket. You may consider this PYC-AP1. Kindly contact us directly at  for a quotation.

Looking for equivalent model for G2A-432A AC110 relay.

Answer : 

You may consider MY4Z, with indent needed upon order. For ex-stock, you may consider MY4. The difference is the contact whereby MY4 is a single contact structure and MY4Z is a bifurcated contact structure.

Looking for an equivalent model for DSP1-DC12V AGP2013.

Answer :

You may consider G6B-2114P-US. Please take note that there is a slight difference in dimension. Kindly contact us directly at  for a quotation.

What is the difference between a standard relay and a DC switching relay?

Answer : 

For the standard relay, the load connected to the relay can be either 220VAC or 24VDC. For the DC switching relay, the load connected to the relay can be only 110VDC.

What is the difference between LY2-J and LY2?

Answer : 

For LY relays, the -J represents the models with blue casings, for the China and Taiwan regions. We can offer them the normal LY relays, without the -J.

Looking for equivalent IDEC RU4S LY4.

Answer : 

You may consider LY4 DC24 and AC230.

Looking for equivalent MY4J AC110/120V model.

Answer : 

You may consider MY-GS.

Looking for an equivalent for IDEC RY2KS-U latching relay series, with separate SET and RESET coils.

Answer : 

You may consider MM2KP. Kindly refer to the datasheet here.

Looking for the equivalent of YM4-L, AC200/220 with a contact rating of 3A at AC220/DC24 and YM4-LDG, DC24.

Answer : 

You may consider MY4N-GS AC220/240 with a contact rating of 3A at AC220/DC24 and MY4N-D2 DC24 with a contact rating of 3A at AC220/DC24 based on its physical outlook.

What is the difference between relay and contactor? 

Answer: 

There is a lot of confusion around the industry about the difference between Relays and Contactors.

Relays are used to control contacts of an electrical circuit due to a change of parameters or conditions in the same circuit or any other associated circuit.

Contactors, on the other hand, are used to interrupt or establish connections in an electrical circuit repeatedly under different conditions.

Can PFY08A-E can be used as a replacement for MY2F-D-G?

Answer :

Any 2 poles socket can be mounted with MY2, can also be used with MY2F. The model you need will depend on the mounting methods.

Looking for equivalent model with the following criteria of : 24VDC operation voltage and 2NO + 2NC.

Answer :

You may consider LY2N-D2 DC24 + PTF08A-E. Kindly note that our socket do not come with build in diode.

Looking for equivalent model for Tyco Electronic R10-T1P2-115F.

Answer : 

You may consider MKS2P.

Looking for equivalent model for DRM270730LT.

Answer :

You may consider LY2N AC220/240.

Looking for equivalent model for DRM570730LT.

Answer :

You may consider LY4N AC200/220.

Looking for equivalent model for DRM270024LT.

Answer :

You may consider LY2N DC24.

Looking for equivalent model for DRM570024LT.

Answer : 

You may consider LY2N DC24.

Looking for equivalent model for G6D-F4B.

Answer :

You may consider P6DF-F4B.

Looking for equivalent model for G6A-434P-ST20-US-DC12.

Answer : 

Sorry, there is no direct replacement for this model. The equivalent model is G6A-274P-ST15-US x 2pcs.

Looking for equivalent model for RV8H-L-AD24.

Answer :

You may consider G2RV-SR700 AC/DC24.

Looking for equivalent model for G6A-434P-ST20-US-DC12.

Answer :

Sorry, there is no direct replacement for this model. You may consider G6A-274P-ST15-US x 2pcs. Kindly note that the wiring and mounting need to change. The dimension is different from the previous model.

Looking for equivalent model for M4-L-D012.

Answer :

You may consider LY4N DC12 with socket PTF14A-E.

Looking for equivalent model for Murr 5200.

Answer :

You may consider G2RV-SR700 DC24.

Looking for equivalent model for HL2-H-DC24V, HL2-PS-K & HL2-SFD-K.

Answer :

You may consider LY2 DC24PT08-0 & PTF08A-E + PYC-A1.

Looking for equivalent model for HJ4-SFD-S, HJ4-DC24V & HC4-PS-K-K.

Answer :

You may consider PTF14A-ELY4 DC24 & PT14-0.

Looking for equivalent model for HJ2-DC24V & HC2-PS-K.

Answer : 

You may consider LY2 DC24 & PT08-0.

Looking for equivalent model for HJ4-AC220/240V.

Answer :

You may consider LY4 AC200/220 & PTF08A-E.

Looking for equivalent model for HJ2-SFD-S.

Answer :

You may consider PTF08A-E.

Looking for equivalent model for 700-HP32Z24,24V.

Answer :

You may consider G2R-2 DC24. Kindly note that the contacting rating is only up to 5A instead of the requested 8A.

Looking for equivalent model for Goodsky RE-408A.

Answer :

You may consider LY4 AC200/220. Kindly check on the output load and voltage.

Looking for equivalent model for MK3PN-5-S AC120 which has been discontinued.

Answer :

You may consider MKS3PIN-5 AC120.

Can MY2K can be replace by MY2IN?

Answer :

No, because MY2IN do not have a reset input.

Looking for equivalent model for MK3P5-S DC24.

Answer :

You may consider MKS3PI DC24.

Looking for equivalent model for Phoenix Control Relays, NS 35/7.5.

Answer :

Sorry, we do not carry such brand. You may consider Omron PFP-100N 1M.

Looking for equivalent model for Idec Control Relays, RJ2S-CLD-D12.

Answer :

Sorry, we do not carry such brand. You may consider Omron G2R-2-SND DC12.

Looking for equivalent model for Idec Control Relays, RJ2S-CLD-D24.

Answer :

Sorry, we do not carry such brand. You may consider Omron G2R-2-SND DC24.

Looking for equivalent model for Idec Control Relays, SJ2S-05B.

Answer :

Sorry, we do not carry such brand. You may consider Omron P2RF-08-E.

Looking for equivalent model for MK3P-I 24VDC.

Answer : 

You may consider MKS3P DC24.

Looking for equivalent model for Mitsubishi RPA3P.

Answer :

You may consider MK3P-2 DC125.

Looking for equivalent model with the following criteria of: 

1) 5A 

2) 4 Poles 

3) 14 Pins 

4) 230V

Answer :

You may consider LY4 series.

Looking for equivalent model for Idec Control Relay RP2P-U 230VAC.

Answer :

You may consider MKS2P AC220 + PF083A-E.

Looking for equivalent model for SZR-MY4-N1 DC24.

Answer :

You may consider MY4N-GS DC24.

Looking for equivalent model with the following criteria of: 

1) Coil Voltage-110VDC 

2) Min Contact Rating- 5A (110VDC) 

3) Contact Configuration-SPST or DPDT or SPDT

Answer :

You may consider MKS series + socket P7MF-06. Kindly check if required any test button or indicator.

Looking for equivalent model for G2M-1123T DC24.

Answer :

You may consider G8HN series, but we are unable to sell it as this is under Automotive relay product.

Can Omron MY2N be replaced with Omron MY2N-GS?

Answer :

Yes. Kindly make sure the model you are using is MY2N not MY2N(S) as it has different current rating.

Looking for equivalent model for AHN211Y0 200/220VAC.

Answer :

You may consider G2R-2-SN AC200/220.

Kindly advise the Mean Time Between Failure (MTBF) of the product.

Answer :

Please refer to the following website: https://www.omron-ap.com/service_support/FAQ/FAQ03424/index.asp.

Looking for equivalent model for ZETTLER AZ763-1AE-5DE.

Answer :

You may consider G2R-1A DC5. Kindly note that it is not a direct 1-1 replacement and rated load only 10 A at 250 VAC.